TECHNICAL SPECIFICATIONS FOR CONSTRUCTION AND



MANAGEMENT OF SENSITIVE COMPARTMENTED INFORMATION FACILITIES
 
VERSION 1.1       IC Tech Spec‐for ICD/ICS 705

 
Intelligence Community Directive (ICD) 705, Physical and Technical Security Standards for Sensitive Compartmented Information Facilities (ICS-705-1) and Standards for Accreditation and Reciprocal Use of Sensitive Compartmented Information Facilities (ICS-705-2) and supersedes Director of Central Intelligence Directive (DCID) 6/9.
 
SCIF Window Criteria (pg. 13)
1. Every effort should be made to minimize or eliminate windows in the SCIF especially on the ground floor.
2. Windows shall be non-opening.
3. Windows shall be protected by security alarms in accordance with Chapter 7 when
they are within 18 feet of the ground or an accessible platform.
4. Windows shall provide visual and acoustic protection.
5. Windows shall be treated to provide RF protection when recommended by the CTTA. (Visit www.signalsdefenses.com for RF window film specifications. SD1000 SD1010 SD2500 SD2510
6. All windows less than 18 feet above the ground or from the nearest platform
affording access to the window (measured from the bottom of the window), shall be
protected against forced entry and meet the standard for the perimeter.