Business Insider
Technology Update
Re-Posted: Monday, December 16, 2013
Signals Defense is a full spectrum security solutions company specializing in Secure Work Environments for the protection of people and information. Signals Defense products and services have been deployed in 1000+ locations including Gov., Intell Agencies, DoD and Fortune 100 companies. We incorporate the 3 security disciplines; IT/Cyber, Technica/EMSEC and Physical/OPSEC to ensure a secure space to protect against cyber attacks, electronic eavesdropping and physical harm.
Showing posts with label DoD. Show all posts
Showing posts with label DoD. Show all posts
Monday, December 16, 2013
Monday, November 4, 2013
Wednesday, May 29, 2013
US military alarmed by breach of critical weapons data to China
by: Press TV
“When the list was read to independent defense experts, they said they were shocked by the extent of the cyber-espionage and the potential for compromising US defenses.”
http://www.presstv.ir/detail/2013/05/29/306046/us-irked-by-theft-of-key-weapons-data/
“When the list was read to independent defense experts, they said they were shocked by the extent of the cyber-espionage and the potential for compromising US defenses.”
http://www.presstv.ir/detail/2013/05/29/306046/us-irked-by-theft-of-key-weapons-data/
Labels:
cyber espionage,
Cyber Security,
DoD,
espionage
Location:
Maryland, USA
Tuesday, February 26, 2013
ICD 705
TECHNICAL SPECIFICATIONS FOR CONSTRUCTION AND
MANAGEMENT OF SENSITIVE COMPARTMENTED INFORMATION FACILITIES
VERSION 1.1 IC Tech Spec‐for ICD/ICS 705
Intelligence Community Directive
(ICD) 705, Physical and Technical Security Standards for Sensitive
Compartmented Information Facilities (ICS-705-1) and Standards for
Accreditation and Reciprocal Use of Sensitive Compartmented Information
Facilities (ICS-705-2) and supersedes Director of Central Intelligence
Directive (DCID) 6/9.
SCIF Window Criteria (pg. 13)
1. Every effort should be made to minimize or eliminate
windows in the SCIF especially on the ground floor.
2. Windows shall be non-opening.
3. Windows shall be protected by security alarms in
accordance with Chapter 7 when
they are within 18 feet of the ground or an accessible
platform.
4. Windows shall provide visual and acoustic protection.
5. Windows shall be treated to provide RF protection when
recommended by the CTTA. (Visit www.signalsdefenses.com for RF window film specifications. SD1000 SD1010 SD2500 SD2510
6. All windows less than 18 feet above the ground or from
the nearest platform
affording access to the window (measured from the bottom of
the window), shall be
protected against forced entry and meet the standard for the
perimeter.